          ST110G

          特點

          ● 優越散熱性能

          ● 優良的耐熱性及可靠性

          ● 較低 Z-axis CTE

          應用領域

          ● PCB散熱解決方案

          ● 汽車電子

          ● DC/ DC逆變器等

          • 產品性能
          • 產品證書
          • 資料下載
          Items Method Condition Unit Typical Value
          Thermal Conductivity ASTM-D5470 A W/ (m?K) 1.0
          Tg 2.4.25D DMA 175
          Td
          2.4.24.6 Wt 5% loss 400
          Thermal Stress 2.4.13.1 288℃, solder float s 300
          T288 2.4.24.1
          TMA

          min

          60
          CTE (Z-axis) 2.4.24 Before Tg ppm/℃ 27
          After Tg ppm/℃ 176
          50-260℃ % 1.8
          Volume Resistivity 2.5.17.1 C-96/35/90 MΩ/cm 1.4x109
          Surface Resistivity
          2.5.17.1
          C-96/35/90 1.5x107
          Dielectric Breakdown 2.5.6 D-48/50+D-0.5/23 kV >45
          Peel Strength (1oz HTE) 2.4.8 288℃/10s N/mm 1.15
          Flammability
          UL94
          C-48/23/50
          Rating
          V-0
          Water Absorption IPC-TM-650 2.6.2.1
          E-1/105+D-24/23 % 0.10

          Remarks:

          1. All the typical value is based onthe 0.5mm specimen(5x106). The Value of water absorption andCTE(Z-axis) is based on the 2.0mm(15x2116).

          2. All the typical values listed above arefor your reference only and not intended for specification. Please contactShengyi Technology Co., Ltd. for detailed information. All rights from thisdata sheet are reserved by Shengyi Technology Co., Ltd.

          3. UL certificated Single/Double sidePCB min. thickness 0.38mm.

          Explanation:C=Humidity conditioning, D=Immersion conditioning in distilled water,E=Temperature conditioning

          The first digit following the letterindicates the duration of preconditioning in hours, the second digit thepreconditioning temperature in ℃ and the third digit the relativehumidity.

          一区二区国产高清视频在线
          <p id="b9cxw"></p>
          1. <td id="b9cxw"></td>

          2. <td id="b9cxw"><ruby id="b9cxw"></ruby></td>
            1. <acronym id="b9cxw"><label id="b9cxw"><xmp id="b9cxw"></xmp></label></acronym>
            2. <li id="b9cxw"><center id="b9cxw"><ol id="b9cxw"></ol></center></li>